U.S. Bellows designed this fabric expansion joint for a gas turbine application. The dimensions for the expansion joint are 153” x 55” x 21”. The fabric belt is made from reinforced neoprene, while the frame and liner are fabricated from A572 Gr.50 carbon steel. The expansion joint is designed for -20°F/+200°F at +/- 100" water column. A dye penetrant examination on the welds was preformed prior to shipment.